VFD selection   total 68 types

Rated power:
0.75kW~7.5kW  11kW~37kW  45kW~90kW  110kW~220kW  250kW~400kW  400kW以上 
Supply voltage:
Single phase220V AC  Three phase 220V AC  Three phase 380V AC 
Type of load:
Constant power(L)  Constant torque(G) 
 
Type Suitable power(kW) Output Input Brake unit Cooling method Price(RMB)
Voltage(V) Rated current(A) Overload capacity Rated power(V) Range of voltage(V) Rated current(A)
FV100-4T-0037L 3.7 3-phase 0~rated input voltage 8.8 115% 1 Minute, 160% 0.5 Seconds 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 10.5 Built-in Cooling by fan
FV100-4T-0022L 2.2 3-phase 0~rated input voltage 5.5 115% 1 Minute, 160% 0.5 Seconds 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 5.8 Built-in Cooling by fan
FV100-4T-0015L 1.5 3-phase 0~rated input voltage 3.7 115% 1 Minute, 160% 0.5 Seconds 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 5.0 Built-in Air cooling
CV100-4T-0075G 7.5 3-phase 0~rated input voltage 17.0 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 20.5 Built-in Cooling by fan
CV100-4T-0055G 5.5 3-phase 0~rated input voltage 13.0 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 14.5 Built-in Cooling by fan
CV100-4T-0037G 3.7 3-phase 0~rated input voltage 8.8 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 10.5 Built-in Cooling by fan
CV100-4T-0022G 2.2 3-phase 0~rated input voltage 5.5 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 5.8 Built-in Cooling by fan
CV100-4T-0015G 1.5 3-phase 0~rated input voltage 3.7 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 5.0 Built-in Cooling by fan
CV100-4T-0007G 0.75 3-phase 0~rated input voltage 2.3 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) 3-phase 380V~440V AC; 50Hz/60Hz 320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 3.4 Built-in Cooling by fan
CV100-2S-0022G 2.2 3-phase 0~rated input voltage 10.0 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) single phase 200V~240V AC; 50Hz/60Hz 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 23.0 Built-in Cooling by fan
CV100-2S-0015G 1.5 3-phase 0~rated input voltage 7.5 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) single phase 200V~240V AC; 50Hz/60Hz 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 14.0 Built-in Cooling by fan
CV100-2S-0007G 0.75 3-phase 0~rated input voltage 4.0 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) single phase 200V~240V AC; 50Hz/60Hz 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 8.2 Built-in Cooling by fan
CV100-2S-0004G 0.4 3-phase 0~rated input voltage 2.5 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) single phase 200V~240V AC; 50Hz/60Hz 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 5.3 Built-in Cooling by fan
CV100-2S-0002G 0.2 3-phase 0~rated input voltage 1.3 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality) single phase 200V~240V AC; 50Hz/60Hz 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 2.3 Built-in Cooling by fan
FV100-2T-0075G 7.5 3-phase 0~rated input voltage 30 150% 1 Minute; 180% 10 Seconds; 200% 0.5 Second; 10 minutes interval(inverse time limit speciality) 3-phase 200V~240V AC; 50Hz/60Hz 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% 35 Built-in Cooling by fan

Remark:*1.The products of "G"type that is over 185kW have standard external DC reactor;Only FV series have the rated power of more than 90kW
   *2.The products of "L"type that is over 200kW have standard external DC reactor;Only FV series have the rated power of more than 110kW

 
 
 