FV100-4T-2500G
|
250 |
3-phase 0~rated input voltage |
470 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
437 |
External brake unit |
Cooling by fan |
|
FV100-4T-2200G
|
220 |
3-phase 0~rated input voltage |
426 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
385 |
External brake unit |
Cooling by fan |
|
FV100-4T-2000G
|
200 |
3-phase 0~rated input voltage |
380 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
352 |
External brake unit |
Cooling by fan |
|
FV100-4T-1850G
|
185 |
3-phase 0~rated input voltage |
350 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
326 |
External brake unit |
Cooling by fan |
|
FV100-4T-1600G
|
160 |
3-phase 0~rated input voltage |
304 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
320 |
External brake unit |
Cooling by fan |
|
FV100-4T-1320G
|
132 |
3-phase 0~rated input voltage |
252 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
240 |
External brake unit |
Cooling by fan |
|
FV100-4T-1100G
|
110 |
3-phase 0~rated input voltage |
210 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
220 |
External brake unit |
Cooling by fan |
|
FV100-4T-0900G
|
90 |
3-phase 0~rated input voltage |
176 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
180 |
External brake unit |
Cooling by fan |
|
FV100-4T-0750G
|
75 |
3-phase 0~rated input voltage |
152 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
157 |
External brake unit |
Cooling by fan |
|
FV100-4T-0550G
|
55 |
3-phase 0~rated input voltage |
110 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
113 |
External brake unit |
Cooling by fan |
|
FV100-4T-0450G
|
45 |
3-phase 0~rated input voltage |
90 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
92 |
External brake unit |
Cooling by fan |
|
FV100-4T-0370G
|
37 |
3-phase 0~rated input voltage |
75 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
76 |
Built-in(optional) |
Cooling by fan |
|
FV100-4T-0300G
|
30 |
3-phase 0~rated input voltage |
60 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
62 |
Built-in(optional) |
Cooling by fan |
|
FV100-4T-0220G
|
22 |
3-phase 0~rated input voltage |
45 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
46.5 |
Built-in(optional) |
Cooling by fan |
|
FV100-4T-0185G
|
18.5 |
3-phase 0~rated input voltage |
37 |
150% 1 Minute, 180% 10 Seconds |
3-phase 380V~440V AC; 50Hz/60Hz |
320V~460V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5% |
38.5 |
Built-in(optional) |
Cooling by fan |
|