Kinco Logo
 
 

Kinco CV100-2S-0004G VFD

  • Voltage(V): 3-phase 0~rated input voltage
  • Overload capcity: 150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality)
  • Rated voltage/frequency: Sigle phase 200V~240V AC; 50Hz/60Hz
  • Allowable voltage range: 180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5%
 

Technical Specifications

ModelCV100-2S-0004G
The power of suitable motor(kW)0.4
Voltage(V)3-phase 0~rated input voltage
Rated current(A)2.5
Overload capcity150% 1 Minute; 180% 10 Seconds; 10 minutes interval(inverse time limit speciality)
Rated voltage/frequencySingle phase 200V~240V AC; 50Hz/60Hz
Allowable voltage range180V~260V AC; Voltage unbalancedness:≤3%; Allowable frequency fluctuation:±5%
Rated current(A)5.3
Brake unitBuilt-in
Protection classIP20
Cooling methodCooling by fan

Dimensions (Unit:mm)

下载失败






ModelsWHDW1H1D1T1Installation
hole(d)
Weight
(Kg)
CV100-2S-0002G85142122731301121050.8
CV100-2S-0004G85142122731301121050.8
CV100-2S-0007G85142122731301121050.8
CV100-2S-0015G85142122731301121050.8
CV100-2S-0022G101152127891401171051
CV100-4T-0007G101152127891401171051
CV100-4T-0015G101152127891401171051
CV100-4T-0022G101152127891401171051
CV100-4T-0037G125220178109.5205165105.53.4
CV100-4T-0055G125220178109.5205165105.53.4
CV100-4T-0075G125220178109.5205165105.53.4

 
 

Easy Solution

 
Facebook GooglePlus
 

tel
Sales:

+86 755 26585555-345

Technical:

+86 755 26585555-337

 
 
Copyright © 2015 Kinco Automation