Only 65mm wide, easy of installation;
European crimping terminal, IO terminals without tightening screws, can improve install efficiency by 30%;
Support network port connected to external keyboard and use standard MODBUS communication protocol and scheme;
Various frequency given channel selections such as panel, analog, communication, pulse, PID, multi-speed, etc.
Built-in AVR, over-modulation, instantaneous non-stop and other functional design, can adapt to complex grid environment;
High-performance VF control algorithm that can achieve full speed range of rated frequency (except zero speed) with 150% load stable operation;
High-performance SVC control for stable operation with 150% load over the full speed range of the rated frequency.
Voltage: Single-phase 220V/0.4-2.2kW and Three-phase 380V/0.75-5.5kW
Communication: Modbus RS485
■ Major Features:
• Overcurrent suppression protection: real-time current monitoring, automatically limit the current to no more than the overcurrent suppression point;
• Overvoltage suppression protection: When no brake resistor is connected, the operating frequency is automatically adjusted or the bus voltage rise is suppressed by flux braking.
• Undervoltage suppression protection (instantaneous non-stop): It can realize the function of instantaneous power loss without stopping;
• Wave-by-wave current limiting: When the sudden load or abnormal conditions such as momentary spikes in the current occurs, it will trigger the wave-by-wave current limit protection, which can limit the rise of the current to a certain extent, so that the current does not exceed the protection value of the inverter, and avoid reporting overcurrent fault and shutdown;
• Heat dissipation treatment: Independent air duct design, close to the IGBT power device efficient cooling, while the software built-in automatic reduction of carrier frequency according to temperature rise;
• Overvoltage, overcurrent fault protection;
• Input phase loss: Detect input phase loss based on bus voltage fluctuations. When phase loss occurs, a certain load is required to detect it;;
• Output phase loss: Output phase loss fault can be quickly detected before and during operation;
• Phase to phase short circuit and short circuit to ground fault: quickly detected within 20ms before operation;
• Inverter module overtemperature, parameter self-learning failure, current detection failure, SVC stall failure, etc.
■ Industry applications
• HVAC, sewage treatment, manufacturing production lines, fan ventilation systems, logistics and transportation, air conditioner cooling systems, woodworking machinery, and various automated production equipment and other industries.
■ Specifications of KC100 Series Inverter
Inverter model | Power supply capacitykVA | input currentA | output currentA | Adaptive motorkW |
single-phase 200-240V 50Hz/60Hz | ||||
KC100-2S-0R40G | 1.0 | 5.3 | 2.5 | 0.4 |
KC100-2S-0R75G | 1.5 | 8.2 | 4.0 | 0.75 |
KC100-2S-01R5G | 3.0 | 14.0 | 7.5 | 1.5 |
KC100-2S-02R2G | 4.0 | 23.0 | 10.0 | 2.2 |
three-phase 380-480V 50Hz/60Hz | ||||
KC100-4T-0R75G | 1.5 | 3.4 | 2.3 | 0.75 |
KC100-4T-01R5G | 3.0 | 5.0 | 3.7 | 1.5 |
KC100-4T-02R2G | 4.0 | 5.8 | 5.5 | 2.2 |
KC100-4T-03R7G | 5.9 | 10.5 | 8.8 | 3.7 |
KC100-4T-05R5G | 8.5 | 14.5 | 13.0 | 5.5 |
For more information, please download and consult the selection manual.