English
  • KC100 series inverter
  • KC100 series inverter
  • KC100 series inverter
KC100 series inverter
KC100high-performance vector inverter

Narrow book-shape design, as small as 65mm, can be rail, vertical, side mounted;

European crimping terminal, 10 terminals without tightening screws, can improve assembly efficiency by 30%;

Support network port connected to external keyboard and use standard MODBUS communication protocol and scheme;

Various frequency given channel selections such as panel, analog, communication, pulse, PID, multi-speed, etc.

Built-in AVR, over-modulation, instantaneous non-stop and other functional design, can adapt to complex grid environment;

High-performance VF control algorithm that can achieve full speed range of rated frequency (except zero speed) with 150% load stable operation;

High-performance SVC control for stable operation with 150% load over the full speed range of the rated frequency.

Product Information

Voltage class: Single-phase 220V model 0.4-2.2kw and Three-phase 380V model 0.75-5.5kw

Telecommunication: MODBUS communication protocol supporting 485 standard




■ Major Features:

   • Overcurrent suppression protection: real-time current monitoring, automatically limit the current to no more than the overcurrent suppression point;

   • Overvoltage suppression protection: When no brake resistor is connected, the operating frequency is automatically adjusted or the bus voltage rise is suppressed by flux braking.

   • Undervoltage suppression protection (instantaneous non-stop): It can realize the function of instantaneous power loss without stopping;

   • Wave-by-wave current limiting: When the sudden load or abnormal conditions such as momentary spikes in the current occurs, it will trigger the wave-by-wave current limit protection, which can limit the rise of the current to a certain extent, so that the current does not exceed the protection value of the inverter, and avoid reporting overcurrent fault and shutdown;

   • Heat dissipation treatment: Independent air duct design, close to the IGBT power device efficient cooling, while the software built-in automatic reduction of carrier frequency according to temperature rise;

   • Overvoltage, overcurrent fault protection;

   • Input phase loss: Detect input phase loss based on bus voltage fluctuations. When phase loss occurs, a certain load is required to detect it;;

   • Output phase loss: Output phase loss fault can be quickly detected before and during operation;

   • Phase to phase short circuit and short circuit to ground fault: quickly detected within 20ms before operation;

   • Inverter module overtemperature, parameter self-learning failure, current detection failure, SVC stall failure, etc.



■ Industry applications


   • It can be widely used in sewage treatment, manufacturing production lines, fan ventilation systems, logistics and transportation, air conditioner cooling systems, woodworking machinery, and various automated production equipment and other industries.


■ Specification, model and technical parameters of KC100 series inverter

Inverter modelPower supply capacitykVAinput currentAoutput currentAAdaptive motorkW
single-phase 200V~240V50Hz/60Hz
KC100-2S-0R40G1.0 5.3 2.5 0.4 
KC100-2S-0R75G1.5 8.2 4.0 0.75 
KC100-2S-01R5G3.0 14.0 7.5 1.5 
KC100-2S-02R2G4.0 23.0 10.0 2.2 
three-phase 380V~480V 50Hz/60Hz
KC100-4T-0R75G1.5 3.4 2.3 0.75 
KC100-4T-01R5G3.0 5.0 3.7 1.5 
KC100-4T-02R2G4.0 5.8 5.5 2.2 
KC100-4T-03R7G5.9 10.5 8.8 3.7 
KC100-4T-05R5G8.5 14.5 13.0 5.5 


For more information, please download and consult the selection manual.