KC200 series general vector inverter

The wide voltage design makes it suitable for all kinds of power grids and power supply conditions at home and abroad;

High performance SVC control , can achieve stable operation with 150% load in the full speed range of the rated frequency;

Support network port connected to external keyboard;

Support standard MODBUS and CANopen communication schemes;

EMC filter can be selected to optimize the electrical environment of EMC field equipment;

Product Information

Voltage:Single-phase 200V~240V/0.4-2.2kW

                 Three-phase 380V~480V/0.75-560kW




■ Major Features

   • Overcurrent suppression protection: real-time current monitoring, automatically limit the current to no more than the overcurrent suppression point;

   • Overvoltage suppression protection: When the brake resistance is not connected, the operating frequency can be automatically adjusted or the magnetic flux braking can ensure that the AC drive will not cause overvoltage protection due to high bus voltage during operation;

   • Undervoltage suppression protection (instantaneous non-stop): It can realize the function of instantaneous power loss without stopping;

   • Wave-by-wave current limiting: When the sudden load or abnormal conditions such as momentary spikes in the current occurs, it will trigger the wave-by-wave current limit protection, which can limit the rise of the current to a certain extent, so that the current does not exceed the protection value of the inverter, and avoid reporting overcurrent fault and shutdown;

   • Heat dissipation treatment: Independent air duct design, close to the IGBT power device efficient cooling, while the software built-in automatic reduction of carrier frequency according to temperature rise;

   • Overvoltage, overcurrent fault protection;

   • Input phase loss: Detect input phase loss based on bus voltage fluctuations. When phase loss occurs, a certain load is required to detect it;

   • Output phase loss: Output phase loss fault can be quickly detected before and during operation;

   • Phase to phase short circuit and short circuit to ground fault: quickly detected within 10ms before operation;

   • Inverter module overtemperature, parameter self-learning failure, current detection failure, SVC stall failure, etc;


■ Industry applications

    KC200 can be used to drive textiles, machine tools, packaging, food, fans, water pumps and various automated production equipment


■ Specifications of KC200 series inverter


Inverter ModelPower capacity
kVA
Input Current
A
Output Current
A
Adaptive motor
kW
Single-phase 200V~240V  50Hz/60Hz
KC200-2S-0R40G15.32.50.4
KC200-2S-0R75G1.58.240.75
KC200-2S-01R5G3147.51.5
KC200-2S-02R2G423102.2
Three-phase 380V~480V  50Hz/60Hz
KC200-4T/5T-0R75G1.53.42.30.75
KC200-4T/5T-01R5G2.553.71.5
KC200-4T/5T-02R2G3.65.85.52.2
KC200-4T/5T-03R7G5.810.58.83.7
KC200-4T/5T-05R5G8.614.5135.5
KC200-4T/5T-07R5G1120.5177.5
KC200-4T/5T-0011G16.5262511
KC200-4T/5T-0015G21353215
KC200-4T/5T-0018G24.538.53718.5
KC200-4T/5T-0022G29.546.54522
KC200-4T/5T-0030G39.5626030
KC200-4T/5T-0037G49.5767537
KC200-4T/5T-0045G59929045
KC200-4T/5T-0055G72.511311055
KC200-4T/5T-0075G10015715275
KC200-4T/5T-0090G11618017690
KC200-4T/5T-0110G138260210110
KC200-4T/5T-0132G166232252132
KC200-4T/5T-0160G200282304160
KC200-4T/5T-0185G230326350185
KC200-4T/5T-0200G250352380200
KC200-4T/5T-0220G280385426220
KC200-4T/5T-0250G309437470250
KC200-4T/5T-0280G342491520280
KC200-4T/5T-0315G395580600315
KC200-4T/5T-0355G437.5624665355
KC200-4T/5T-0400G629670725400
KC200-4T/5T-0450G715792820450
KC200-4T/5T-0500G800835950500
KC200-4T/5T-0560G8969201020560